Knee Impact Test Fixture TE-550/TE-550-E
The Knee Impact Test Fixture meets the specifications listed under CFR 49, Part 572. One uniaxial accelerometer, one uniaxial femur load cell and one linear potentiometer are required but not included. Five channels are require to run the Knee Impact Test Fixture.
Part number TE-550 is designed for 110-volt, 60-Hz AC power and TE-550-E is designed for 240-volt, 50-Hz AC power. The fixture does not include transducers for measuring force, displacement or acceleration. Data acquisition equipment and processing software are available and can be ordered separately to meet specific requirements.
First Technology Safety Systems can provide turnkey certification equipment and systems services. This includes certification, data acquisition equipment and software installation, with complete system operation testing and training for all components.

Technical Specifications
Fixture Dimensions
| Length | 87 Inches |
| Width | 47 Inches |
| Height | 123 Inches |
Equipment Included
TE-530-002 |
Main Frame Weldment |
TE-530-004 |
Middle Impact Fixture Assembly |
TE-530-014 |
Knee Impact Prove for Hybrid III 50th and 95th PercentileIncludes 5.0 Kg (11.0 lbs) test prove, velocity vance, and suspension cables
|
TE-512-30 |
Knee Shear Prove for Hybrid III 50th and 95th PercentileIncludes 12 Kg (26.46 lbs) test probe, velocity vane, and suspension cables |
TE-512-109 |
Load Distribution Bracket - H3-50thRequired for knee sheer test. Includes six (6) ALC foam pads for impact surface |
Optional Equipment
TE-515-000 |
Knee Impact Probe for Hybrid III 5th PercentileIncludes 3.0 Kg (6.6 lbs) test probe and suspension cable
|
TE-540P |
Knee Shear Probe for Hybrid III 5th PercentileIncludes 7.21 Kg (16.0 lbs) test probe and suspension cables
|
TE-518 |
Load Distribution Bracket, Hybrid III 5th Percentile |
TE-2511 |
Knee Impact Probe for Hybrid III 6 Year OldIncludes 0.82 Kg (1.8 lbs) test probe and suspension cables
Requires One (1) Uniaxial Accelerometer 7264C-2000
|
TE-2508 |
Femur Load Cell Adaptor for Hybrid III 6 YO &/or Hyrbrid III 10 YOAllows Hybrid III Six Year old Knee assembly to be tested on TE-550 Hybrid III knee impact test apparatus
|
TE-512-120 |
Load Distribution Bracket, Hybrid III 95th |
TE-2513 |
Knee Impact Probe, Hybrid III 10 YO |
TE-320-141 |
Hybrid II Knee Impact StoolStool with stainless steel seating surface, mount to hydraulic lift table for Hybrid II knee impact
|
Featured Products
- Test Equipment Matrix
- A tool used to determine Test Equipment model numbers for each dummy type and location...
- Load Cell Matrix
- A tool used to determine Load Cell model numbers for each dummy type and location...
- SID IIs
- A new generation crash test dummy to specifically evaluate advanced automotive side impact protection systems...
- Ejection Mitigation Headform
- The 18 kg headform consists of a vinyl skin on an aluminum skull...